• PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm
  • PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm
  • PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm
  • PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm
PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm

Product Details:

Place of Origin: Jiangsu, China
Brand Name: XL
Certification: SGS
Model Number: XL-500-S WAVE

Payment & Shipping Terms:

Minimum Order Quantity: 10 square meters
Price: $1.2-2/square meters
Packaging Details: Wooden,cartons,custom package
Delivery Time: 10 working days
Payment Terms: Western Union, T/T, MoneyGram, D/P, D/A, L/C
Supply Ability: 1000m2/per pay
Get Best Price Contact Now

Detail Information

Condition: New PVC Material Cooling Type: Cooling Tower Parts
Material: PVC,PP,CPVC Warranty: 1 Year
Name: Counter Flow S Wave Pvc Sheet For Cooling Tower Fill/filling/pvc Packing Width: 500mm
Wave Height: 31/33mm Usage: Cooing Tower
MOQ: 10 Square Meters Thickness: 0.32-0.6mm
Length: 1000/2000 Mm/customized
Highlight:

Cooling Tower Film Fill S Wave

,

Cooling Tower Film Fill S Wave

,

Counter Flow Media 33mm

Product Description

Counter flow S wave pvc sheet for cooling tower fill/filling/pvc packing

Description:

With cooling towers, fill selection is a critical aspect in this regard. High efficiency film fill may seem the most desirable option. However, if poor water quality causes this fill to rapidly foul and plug, it may incur excessive maintenance costs.

Most cooling towers now utilize film fill to enhance air/water contact. Film fill, as the name implies, induces the cooling water to form a film on the material surface. The filming mechanism maximizes liquid surface area. A guiding principle behind fill design and selection “is to increase air-to-water contact, driving up convection and evaporative cooling while reducing pressure drop in the system”

CF500mm cross fluted fills typically provide high specific surface area and high thermal performance but exhibit poor anti-fouling characteristics due to the geometry that forces many deviations to the flow path.
Flute spacing significantly affects fill performance; smaller spacing increases the surface area but also raises the potentialseverity of fouling.

Specifications:
 
Tech Date  
Sheet Width(mm) 500mm
Sheet Length 1000/2000mm/customized 
Thickness 0.32-0.6mm/customized
Sheet Spacing 30/33mm
Color grey/white/black
Material PP/PVC/CPVC

 

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 1PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 2PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 3

 

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 4

 

Related Cooling Tower Film Fill

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 5

*This type is a film fill system designed for counterflow towers offering you several distinct advantages.
Crossed corrugations provide the surface area and turbulence to develop efficient heat transfer. The corrugations inherently establish uniform fill sheet spacing at 0.75.

*Using MC75 film fill in place of existing splash type fill in counterflow towers usually means reduced fill height, which translates into reduced pumping head. MC75 will also provide greater cooling tower capacity, which means your current performance level will require less fan energy.

*The fill pack depth(air travel) is variable to provide the proper heat transfer area within a single fill layer. If another layer of fill is necessary for situations where additional air travel is required, it will be limited to only one. Limiting the number of interfaces between packs minimizes restrictions that usually cause fill clogging. MC75 counterflow fill can be hung from structural members or it can be bottom-supported in virtually all counter-flow cooling towers, regardless of a cooling tower's age or manufacturer.

 

PACKING AND DELIVERY

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 6

 

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 7

 

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 8

About US

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 9

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 10

 

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 11

 

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 12

 

PVC Counter Flow Media Cooling Tower Film Fill S Wave 31/33mm 13

Q: Are you trading company or manufacturer ?
A: We are manufacturer with our own factory.


Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. Or it is 15-20 days if the goods are not in stock, it is according to quantity.


Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge. And the freight cost will on the buyer's side.


Q: What is your terms of payment ?
A: Payment<=USD1000, 100% in advance. Payment>=USD1000, 30% T/T in advance ,balance before shipment.